Engineering Calculator Worked Examples

HAND CHECK THE MATH

WORKED EXAMPLES

CALCULATIONS, STEP BY STEP

Find your worked example.

27 examples
Heat transfer

AI chips in space

Follow heat through a coated radiator panel into space.

7.28 kW from 100 ft²

View example ↗

Darcy friction factor

Hand-check the Colebrook-White Darcy friction factor at Reynolds number 100,000 and relative roughness 0.001.

Expected: Darcy f = 0.0222

Fluid flow
View example

Equipment cost scaling

Hand-check a hypothetical equipment cost estimate from 1,000 to 2,000 US gallons using the six-tenths rule for two units.

Expected: $151,571.66 per unit · $303,143.31 total

Cost estimation
View example

Gas control valve

Check required gas valve Cv for a supplied standard flow and subcritical pressure drop.

Expected: Required Cv = 4.14

Fluid flow
View example

Gas-flow conversion

Convert 100 reference ft³/min of dry air at 60°F and 14.7 psia to actual flow at 100°F and 100 psia, with Z equal to 1.

Expected: 100 reference ft³/min → 15.8 ACFM

Fluid flow
View example

Heat duty

Hand-check sensible heating of 10,000 lb/h from 70°F to 150°F using a specific heat of 4.18 kJ/(kg·K).

Expected: 234 kW of heating

Heat transfer
View example

Heat exchanger

Size the thermal conductance of a counterflow exchanger from two mass flows and the hot outlet temperature.

Expected: 599,000 Btu/h · cold outlet 110°F

Heat transfer
View example

Horizontal tank volume

Hand-check liquid volume in a flat-ended horizontal cylindrical tank with a 6 ft internal diameter, 12 ft length and 2 ft liquid depth.

Expected: 741 US gal · 29.2% full

Mechanical design
View example

K-factor and equivalent length

Convert an assumed loss coefficient K of 5 into equivalent pipe length using a 2.07-inch bore and Darcy friction factor of 0.02.

Expected: 43.1 ft equivalent length

Fluid flow
View example

Lang-factor cost estimate

Apply a hypothetical custom Lang-style factor to purchased equipment cost. Remove existing example rows and enter exactly the three rows below.

Expected: $1,200,000 total estimated plant cost

Cost estimation
View example

Liquid orifice flow

Hand-check liquid orifice flow for a 2-inch bore in a 4-inch pipe, 5 psi differential pressure, Cd of 0.62 and density of 62.4 lbm/ft³.

Expected: 171 US gpm

Fluid flow
View example

Liquid valve Cv

Hand-check liquid valve Cv, flow, and pressure drop for 100 gpm, 16 psi, and specific gravity of 1.

Expected: Required Cv = 25

Fluid flow
View example

Material balance

Hand-check a mixer, dilution and solids separation in lb/h. Follow each component balance, calculate compositions and compare residuals.

Expected: 1,500 lb/h product · 66.7 wt% water

Process engineering
View example

Multi-section pipe system

Hand-check two pipe sizes, fittings, a sudden expansion, an exchanger and a 25 ft lift at 50 US gpm. See every pressure-budget term.

Expected: 18.4 psi · 42.6 ft of head

Fluid flow
View example

Multilayer heat transfer

Check conduction through two flat layers with prescribed surface temperatures. Remove all default layers and add exactly two conduction layers, ordered from side A to side B.

Expected: 3,470 Btu/h · interface 84.4°F

Heat transfer
View example

NPSH available

Calculate NPSH available for a pump above an open tank. Compare normal level, low level and increased suction losses using absolute pressures.

Expected: NPSH available is 6.61 m, leaving 3.61 m above the assumed NPSH required. A lower tank level and higher suction loss can remove that margin.

Pumps
View example

Pipe friction loss

Hand-check Darcy–Weisbach and Colebrook for 50 US gpm through 150 ft of 2-inch pipe, including fitting losses and unit conversions.

Expected: 3.61 psi friction loss

Fluid flow
View example

Pipe insulation heat loss

Hand-check cylindrical insulation heat loss for a 2.38-inch pipe OD, 1-inch insulation, 200°F wall and 70°F ambient.

Expected: 3,010 Btu/h over 100 ft

Heat transfer
View example

Pipe network

Hand-check a three-pipe loop supplying 100 US gpm through two equal-resistance paths. Includes an EPANET input file and a closed-pipe check.

Expected: 50 gpm per path · 97.6 ft head at B

Networks
View example

Pipe size comparison

Compare 1½, 2 and 2½ inch Schedule 40 pipes at 50 US gpm through 150 ft of pipe. See pressure drop in psi and download each system.

Expected: Total loss falls from 12.2 psi to 3.61 psi with NPS 2, then to 1.54 psi with NPS 2½. The lowest pressure drop does not automatically mean the lowest overall cost.

Fluid flow
View example

Pipe sizing

Hand-check the minimum pipe diameter and Schedule 40 selection for 100 US gpm with a 6 ft/s velocity limit.

Expected: NPS 3 Schedule 40 · 4.34 ft/s

Fluid flow
View example

Pipe velocity

Hand-check average velocity for 100 US gpm through a 2.07-inch inside diameter using pipe area and continuity.

Expected: 9.56 ft/s

Fluid flow
View example

Pipe wall thickness

Hand-check the implemented straight-pipe pressure equation using hypothetical design inputs and allowances.

Expected: 0.11 in minimum nominal wall

Mechanical design
View example

Pitot-tube velocity

Hand-check pitot velocity for a 0.5 in H₂O differential and air density of 0.075 lbm/ft³, with an optional duct-flow estimate.

Expected: 47.2 ft/s local velocity

Fluid flow
View example

Pump power

Hand-check pump hydraulic and shaft power for 500 gpm, 100 ft of head, 62.4 lbm/ft³ density, and 75% efficiency.

Expected: 16.9 hp required shaft power

Pumps
View example

Reynolds number

Calculate Reynolds number from 6 ft/s, a 2.07-inch bore, density of 62.4 lbm/ft³, and viscosity of 1 cP.

Expected: Re = 96,000 · Turbulent

Fluid flow
View example

Venturi flow

Hand-check venturi flow for a 4-inch pipe ID, 2-inch throat, 5 psi differential, Cd of 0.98 and liquid density of 62.4 lbm/ft³.

Expected: 270 US gpm

Fluid flow
View example

HOW TO USE THESE EXAMPLES

Follow the numbers through.

Each example lists the calculator settings, shows the equations with numbers substituted, and gives intermediate results to compare. Use the same units and assumptions when you check the calculator.

Every example links to its calculator, where you can try a different set of inputs.

Read the calculation methodology