Darcy Friction Factor: Worked Example

Expected answer
Darcy f = 0.0222

Solve the implicit Colebrook–White equation for turbulent pipe flow at Re = 100,000 and ε/D = 0.001. Both inputs are dimensionless, so this result is independent of the length-unit system.

Open calculator

1. Calculator Inputs

Select the units below before entering the numbers. These are fixed benchmark inputs for checking the calculator.

Calculator fieldValueUnit / setting
Reynolds number inputEnter Reynolds number
Reynolds number100,000dimensionless
Roughness inputRelative roughness, ε/D
Relative roughness0.001dimensionless

2. Step-by-step Math

Write the Darcy-form equation

1/√f = −2 log₁₀[ (ε/D)/3.7 + 2.51/(Re√f) ]
f(next) = {−2 log₁₀[0.001/3.7 + 2.51/(100000√f)]}⁻²

The equation contains f on both sides. Use base-10 logarithms and iterate, starting with f = 0.020.

Iterate until the value stops changing

Start:      0.020000000
Iteration 1: 0.022290508
Iteration 2: 0.022168795
Iteration 3: 0.022174821
Iteration 4: 0.022174522
Iteration 5: 0.022174537
Iteration 6: 0.022174536

The fixed-point hand calculation converges to the calculator’s Colebrook–White result. Retain more digits internally than shown here.

Convert Darcy to Fanning

fFanning = fDarcy / 4
fFanning = 0.0221745359445 / 4
fFanning ≈ 0.00554

Use the Darcy value in ΔP = f(L/D)ρV²/2. A Fanning-based pressure-loss equation includes a separate factor of four.

3. Compare Your Answers

Keep full precision during the calculation. The calculator may display fewer digits; compare answers rounded to three significant figures; retain unrounded intermediate values.

ResultExpected answerYour answer
Darcy friction factor0.0222__________
Fanning friction factor0.00554__________
Flow regimeTurbulent__________
MethodColebrook-White__________

Second check

Change Reynolds number to 1,000. The calculator switches to the laminar relation fDarcy = 64/Re = 0.064; fFanning = 0.016. Relative roughness does not enter this fully developed laminar relation.

4. Assumptions and Method

This example concerns conventional single-phase pipe flow. Roughness is specified rather than estimated for a material. Transition-region results use a different treatment and should not be checked with this turbulent iteration.

Equation definitions and implementation: Darcy Friction Factor Calculator. See also calculation methodology and other worked examples.