Venturi Flow: Worked Example

Expected answer
270 US gpm

Estimate liquid flow through a venturi with a 4.000-inch actual pipe inside diameter and a 2.000-inch throat. Use a supplied discharge coefficient of 0.98 and inlet-to-throat differential pressure of 5 psi.

Open calculator

1. Calculator Inputs

Select the units below before entering the numbers. These are fixed benchmark inputs for checking the calculator.

Calculator fieldValueUnit / setting
Solve forFlow rate, Q
Pipe inside diameter4in
Throat diameter2in
Fluid density62.4lbm/ft³
Discharge coefficient, Cd0.98dimensionless
Inlet-to-throat differential pressure5psi

2. Step-by-step Math

Convert geometry and properties

D = 4 × 0.0254 ≈ 0.102 m
d = 2 × 0.0254 ≈ 0.0508 m
β = d/D = 0.5
At = πd²/4 ≈ 0.00203 m²
ρ = 62.4 × 0.45359237 / 0.3048³ = 999.552114535 kg/m³
ΔP = 5 × 6894.757293168 ≈ 34,500 Pa

The stated 4-inch pipe diameter is an actual bore. It does not mean NPS 4 Schedule 40.

Calculate liquid flow

Q = Cd At √[2ΔP / (ρ(1−β⁴))]
Q = 0.98 × 0.00202682991639
    × √[2 × 34473.78646584 / (999.552114535 × 0.9375)]
Q = 0.017037839146 m³/s
Q = 61.336220925 m³/h ≈ 270 US gpm

The coefficient is an input. It has not been inferred from venturi geometry or calibration.

Check throat and pipe velocity

Vthroat = Q/At = 8.406151403 m/s
Vpipe = Q/(πD²/4) = 2.101537851 m/s
Vthroat / Vpipe = (D/d)² = 4

A throat with half the pipe diameter has one quarter of the area, so the average velocity is four times as high.

3. Compare Your Answers

Keep full precision during the calculation. The calculator may display fewer digits; compare answers rounded to three significant figures; retain unrounded intermediate values.

ResultExpected answerYour answer
Liquid flow61.3 m³/h__________
Flow in US units270 gpm__________
Beta ratio0.5__________
Throat velocity8.41 m/s__________

Second check

Select Differential pressure and enter 270.055256094 gpm with the same dimensions, density and Cd. The result returns to 5 psi. Next select Throat diameter with that flow and differential; the result should be 50.8 mm, or 2 inches.

4. Assumptions and Method

Single-phase incompressible flow with a specified Cd. The pressure differential is from inlet to throat, not the permanent downstream pressure loss. This example does not validate meter calibration, cavitation margin, gas expansion or a meter standard.

Equation definitions and implementation: Venturi Flow Calculator. See also calculation methodology and other worked examples.