Inputs
Liquid-water properties reference ↗ · Pure water, 0–99°C at 100 kPa absolute.
Results
Choose your inputs and calculate.
Calculation basis
β = d/D; At = πd²/4 Q = Cd At √[2ΔP / (ρ(1 − β⁴))] ΔP = (ρ/2)(Q/(Cd At))²(1 − β⁴) Throat diameter is obtained by rearranging the same equation.
How to use this calculator
Enter the pipe ID, throat diameter, density, and the discharge coefficient for your meter. Select flow or differential pressure, or solve a throat diameter for a target liquid flow. Cd depends on geometry and operating conditions; verify its validity with the meter manufacturer.
Single-phase incompressible liquid, full pipe, pressure taps at the same elevation. The inlet-to-throat differential is not the permanent pressure loss. This tool does not select an ISO 5167 coefficient or calculate gas expansibility.
References
Explore all engineering tools · Pipe pressure drop calculator
Equation values and input guide
Choose the unknown, then enter the meter dimensions, operating liquid density and a discharge coefficient justified for the meter and pressure taps. The calculated differential is the tap pressure difference, not permanent system loss.
- Q
- Liquid volume flow, converted to m³/s in the equation.
- D, d
- Upstream pipe inside diameter and Venturi throat diameter, respectively, in m after conversion. The restriction diameter must be smaller than the pipe bore.
- β
- Diameter ratio d/D, dimensionless. β⁴ is its fourth power.
- Aₒ or At
- Area of the Venturi throat, πd²/4, in m².
- Cd
- Discharge coefficient, dimensionless. Obtain it from calibration, applicable correlation or vendor information for the operating range.
- ρ
- Operating liquid density in kg/m³.
- ΔP
- Positive pressure difference between the specified taps in Pa after conversion. Supply that differential, not a single pressure reading.
Use the unit selectors beside the inputs. Units shown in the equations must be consistent when checking the math by hand.